6. The Paper Strip

The Paper Strip draws one dot for every beat, the way a printing timegrapher marks its paper. It shows what the readings summarise: how steadily the watch keeps time, beat by beat.

The Paper Strip on an opened take, marks 1 to 14

Reading the Strip

  • Along the strip is time: the take’s minutes and seconds.
  • Across the strip is how early or late each beat came against a perfect clock beating exactly at the nominal beat rate, every 125 ms at 28,800 bph. Early is up, Late down (with Direction set to Down, early is to the right): the words Witschi’s training course uses (doc. 71.1010D35e, p. 6).
  • Tick dots are blue and Tock dots orange (mark 13).
  • The amplitude is drawn over the dots as a violet line, on its own scale at the right (mark 14). The rate and the beat error can be drawn the same way (mark 1).
What you seeWhat it means
Two flat linesThe watch keeps the nominal rate.
Two lines sloping upEach beat comes a little sooner: the watch gains.
Two lines sloping downThe watch loses.
A gap between the two linesThe beat error, timed from the drop.
Lines that bendThe rate is changing.
Dots scattered across the linesJitter: uneven beats, or a poor sound.
A sudden step in both linesA jump: a knock, or lost sound. The readings skip it.
Faint grey dotsBeats in the settling time, or masked. They aren’t read.

A line that runs off one edge comes back on the other, like paper wrapped round a drum. So the strip’s Width is its zoom.

The Toolbar

MarkControlWhat it doesWhy you’d use it
1Draw Over the StripThree switches: the rate (magenta), amplitude (violet, on at first) and beat error (amber) readings drawn as lines over the dots, each on its own scale, written at the right (above the strip with Direction set to Down).To see at a glance whether a wobble in the rate comes with a dip in amplitude.
2WidthHow much time fits across: from ±0.1 ms to ±60 s, typed or picked.Narrow (±1 ms) to see a good watch’s beat error; wide to keep a drifting watch from wrapping.
3LengthHow much time fits along: picked from 10 s to three days; typed (45, 5 min, 2h, 1:30:00) or zoomed, from 2 s up to 80 hours.Short to follow the last few seconds; long to see a whole take.
4FitShows the whole take along the strip, and keeps growing with it.To see everything at once. Zooming or looking back turns it off; changing the width leaves it on.
5Centre and Auto-CentreCentre puts the newest beats on the centre line once. Auto-Centre keeps them there.To bring the trace back after it has wrapped or drifted.
6Rate Line and Parallel GuidesThe Rate reading drawn as a magenta line over the beats it was fitted to, and faint lines at the same slope across the strip. Both on at first.If the dots follow the line, the reading describes them well. The eye judges whether lines are parallel better than it judges a slope.
7MaskLeaves stretches out of the readings. See Masking.To take a knock or a handling stretch out of every reading.
8Position BrushMarks a stretch as one position. See The Position Brush.To correct the position after the fact.
9DirectionAcross (time left to right, the default) or Down (newest at the top, as on the open tg program).Down, if you’re used to a printed strip: a gaining watch leans right as it rises.
10ExportSaves the strip as a PNG or SVG picture.To share it, or put it in a report.

Opening a take turns Fit on and sets the width to the narrowest listed width that holds all the take’s beats without wrapping (one stray dot in a thousand at each end left out), so the whole take shows at once. Listen, or a new test, then brings back the width, length and Fit the strip had before the take was opened. A width or length you changed by hand meanwhile stays as you set it.

Moving Around

ToDo
Look back through the takeThe mouse wheel or a swipe, or drag along the time axis. Back at the newest beat it is live again.
Zoom timeCtrl and the wheel (Cmd on a Mac), or a pinch.
Zoom the widthAlt and the wheel (Option on a Mac).
Slide the trace acrossDrag across the strip.
Return to the newest beatsDouble-click.

Looking back moves the cards too. With the strip moved off the newest beats, the readings cards, the Tick Tock Profile and the Scope read the moment at the strip’s newest edge. The strip’s label says when (“at 0:40”).

The Track

The band along the top of the strip shows where the watch was and what was left out.

MarkPartWhat it shows
11The positionEach stretch in one position, in teal, named at its start.
12SettlingThe solid band after each change of position, while the balance settles. Not read. It then fades over 40 s, so each change shows.
  • Masked stretches show as grey hatching.
  • During and after a Positions Test, the time before the test is left plain. On the track the time the test didn’t use is plain too; on the strip it is hatched.

Masking

The Mask tool on, with 15 seconds masked, marks 1 to 5

What it does: leaves a stretch out of every reading, as if it were a break. Nothing is deleted: the beats stay, faint under hatching.

MarkWhat you see
1Mask, lit while on.
2The masked stretch, named on the track.
3Lines drawn over the strip break there.
4The sparklines on the cards break too.
5Changes not saved, on an opened recording.

How to use it:

  1. Turn on Mask (the scissors).
  2. Drag along the strip over the stretch. A drag under half a second is ignored, as a slip of the mouse.
  3. Drag a masked stretch’s edge to move it.
  4. Click a masked stretch, or right-click it with Mask on or off, to bring it back. Edit > Remove All Masks… brings them all back.

What a mask changes:

  • No reading reaches across one, and nothing inside one is read.
  • A chart’s line comes back only once a whole Average Over time has been heard after it.
  • The charts, the whole-take figures, the Distributions, Steadiness and a Positions Test all leave the masked beats out.
  • A reading whose span takes in masked sound says so in a chip, such as 6.8 s Masked.

Why you’d use it: a bump of the stand, picking the watch up, or a noise in the room shows as a jump or a scatter. Masking it keeps one moment from moving a whole take’s figures.

Saving masks: a saved take keeps its masks, and the command line’s timegrapher session leaves them out too. On a recording opened from disk, File > Save writes them beside it.

The Position Brush

What it does: marks a stretch of the strip as one position, on a live take or one opened. It corrects the position record after the fact.

  1. Pick a position from the brush’s menu (mark 8).
  2. Drag along the strip. A teal preview says the position and the times, such as “CD 4:30 to 5:30”.
  3. Stop Painting, at the end of its menu, or Esc, puts it down.
  • Why: you turned the watch but forgot to press the position button, or a recording from another app has no positions.
  • Painting never starts a settling: it is a correction, not a turn of the watch.
  • The positions recorded stay under the painting. Right-click a painted stretch on the track to take the painting off.
  • Drag a change of position along the track to move it.
  • Greyed during a Power Reserve Test, during or after a Positions Test (the test’s take keeps its own positions), and while nothing is on show yet.

Previous: The Readings Cards and the Calibre Card · Next: The Tick Tock Profile and the Scope

This page comes from the app's user guide at v1.0.1. See it on GitHub.